Opened 11 months ago

Closed 10 months ago

Last modified 3 months ago

#393 closed defect - etc (fixed)

Blnd equivalents of 6lev lines in c13 are missing

Reported by: peter Owned by: nobody
Priority: minor Milestone: C17.01
Component: atomic/molecular data base Version: trunk
Keywords: Cc:

Description

In c17 the 6lev lines were removed. We also made sure that enough levels were included in the stout O I model to capture the Ly beta fluorescence. However, currently this mechanism is broken (see #78).

The 6lev lines gave predictions for full multiplets, while stout resolves all the multiplets into individual lines. For backward compatibility we should add Blnd entries for multiplets that correspond to the old 6lev entries in c13.

Attachments (1)

patch_o1 (4.1 KB) - added by peter 10 months ago.
proposed patch

Download all attachments as: .zip

Change History (5)

Changed 10 months ago by peter

Attachment: patch_o1 added

proposed patch

comment:1 Changed 10 months ago by peter

It turns out that c17 uses enough levels to capture Ly beta pumping in O I, but not enough to fully recover the old 6lev model atom. For the latter 29 levels are needed. Also the way the number of levels was set was messy as it (mis-) used the variable atmdat.nDefaultPhotoLevelsFe for that. It is better to set the number of levels directly in the stout masterfile.

The attached proposed patch fixes all issues that are discussed here, except ticket #78.

comment:2 Changed 10 months ago by peter

Resolution: fixed
Status: newclosed

Fixed with r11730 and r11731 on the trunk, and r11732 on c17_branch.

comment:3 Changed 3 months ago by Gary J. Ferland

Milestone: c17.01 releaseC17.01 release

Milestone renamed

comment:4 Changed 3 months ago by Gary J. Ferland

Milestone: C17.01 releaseC17.01

Milestone renamed