Opened 10 months ago

Closed 10 months ago

Last modified 4 months ago

#399 closed defect - wrong answer (fixed)

Output from SAVE XSPEC command is faulty in fork-based runs

Reported by: peter Owned by: peter
Priority: major Milestone: C17.01
Component: output Version: trunk
Keywords: Cc:

Description

When using the SAVE XSPEC command in a fork-based grid run, the resulting FITS file will contain many blocks of only zeros. This is because the results are not communicated between the various forked instances of the code. MPI-based and sequential runs are fine. MPI-based runs use MPI_Reduce() to communicate the results. There is no equivalent for fork-based runs.

Change History (3)

comment:1 Changed 10 months ago by peter

Resolution: fixed
Status: newclosed

Fixed in r11804 on the trunk and r11805 on c17_branch.

comment:2 Changed 4 months ago by Gary J. Ferland

Milestone: c17.01 releaseC17.01 release

Milestone renamed

comment:3 Changed 4 months ago by Gary J. Ferland

Milestone: C17.01 releaseC17.01

Milestone renamed

Note: See TracTickets for help on using tickets.